Notifications
You must be signed in to change notification settings - Fork 4.4k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Use cleaned PF candidates in UE subtraction in HI miniAOD (112X) #32330
Use cleaned PF candidates in UE subtraction in HI miniAOD (112X) #32330
Conversation
A new Pull Request was created by @mandrenguyen (Matthew Nguyen) for CMSSW_11_2_X. It involves the following packages: RecoHI/HiJetAlgos @perrotta, @jpata, @cmsbuild, @slava77 can you please review it and eventually sign? Thanks. cms-bot commands are listed here
|
@cmsbuild please test |
The tests are being triggered in jenkins.
|
backport of #32325 |
+1 |
Comparison job queued. |
Comparison is ready There are some workflows for which there are errors in the baseline: Comparison Summary:
|
the summary looks kind of broken. @smuzaffar from the recent updates I could possibly blame my cms-sw/cms-bot#1430, but it's odd considering that the results looked fine in the PR tests |
I see some working PR summaries, e.g. in cms-sw/cmsdist#6474 (comment), which was triggered after cms-sw/cms-bot#1430 was merged; so, at least logRootQA is not fully broken |
@slava77 , today there was [a] |
I'm guessing that some special characters in https://cmssdt.cern.ch/SDT/jenkins-artifacts/baseLineComparisons/CMSSW_11_2_X_2020-12-01-1100+5bd579/40234/validateJR/logRootQA.log |
The tests are being triggered in jenkins.
|
This pull request is fully signed and it will be integrated in one of the next CMSSW_11_2_X IBs after it passes the integration tests and once validation in the development release cycle CMSSW_11_3_X is complete. This pull request will now be reviewed by the release team before it's merged. @silviodonato, @dpiparo, @qliphy (and backports should be raised in the release meeting by the corresponding L2) |
-1 Tested at: 82942e0 CMSSW: CMSSW_11_2_X_2020-12-01-1100 I found follow errors while testing this PR Failed tests: UnitTests
I found errors in the following unit tests: ---> test runtestPhysicsToolsPatAlgos had ERRORS |
Comparison job queued. |
Comparison is ready There are some workflows for which there are errors in the baseline: Comparison Summary:
|
please test |
The tests are being triggered in jenkins.
|
+1 |
Comparison is ready Comparison Summary:
|
+1 |
PR description:
In #31668 a cleaning procedure was added to HI miniAOD to remove badly reconstructed particles. This procedure was applied prior to jet clustering (akCs4PFJets), but not applied to the towering algorithm (PFTowers) that is used for the UE subtraction. This leads to an inconsistency with our previous AOD-only workflow. The cleaning is only effective occasionally such that the net effect is a small migration of in the jet pt spectrum.
PR validation:
Wfs 140.5611 and 158.01
if this PR is a backport please specify the original PR and why you need to backport that PR:
Backport of #32325
Needed for HI reMiniAOD in 11_2_X