sw trigger with acquire and parameter file understands submodules
Browse files Browse the repository at this point in the history
  • Loading branch information
tintig committed Jan 15, 2020
1 parent eca2836 commit 9649982
Show file tree
Hide file tree
Showing 2 changed files with 2 additions and 0 deletions.
Binary file modified manual/manual-client/Eiger_short.pdf
Binary file not shown.
2 changes: 2 additions & 0 deletions manual/manual-client/Eiger_short.tex
Original file line number Diff line number Diff line change
Expand Up @@ -176,6 +176,7 @@ \subsection{Mandatory setup - Client}
\begin{verbatim}
sls_detector_put 0-parameters setup.det
\end{verbatim}
Note that the parameter file for any realease before 4.1.1 has not the possibility to understand parameters to be set differently for different half modules, i.e. {\tt{0:txndelay\_left xxxxx},\tt{1:txndelay\_left yyyyy}}.

In the case of \E, the proper bias voltage of the sensor has to be setup, i.e. the {\tt{setup.det}} file needs to contain the line {\tt{vhighvoltage 150}}. Other detector functionality, which are rarely changed can be setup here.
Other important settings that are configured in the {\tt{setup.det}} file are:
Expand Down Expand Up @@ -621,6 +622,7 @@ \section{External triggering options}\label{triggering}
\item {\tt{burst\_trigger}} gets only 1 trigger, but allows to take many frames. With {\tt{frames}} one can change the number of frames. {\tt{cycles}} needs to be 1. {\tt{exptime}} and {\tt{period}} have to be set. In the gui it is called trigger readout.
\item{\tt{gating}} allows to get a frame only when the trigger pulse is gating. Note that in this case the exp time and period only depend on the gating signal. {\tt{cycles}} allows to select how many gates to consider. Set number of frames to 1 using {\tt{frames}}. IMPORTANT: Up to firmware 23, the last subframe is oblige to finish being taken, despite the gate signal going down. This will be configurable from later fw and software version. Also, in gating mode, due to timimg of the state machine, you need to leave 500~$\mu$s deadtime between the end on an acquisition and the next. This is as the state machine is unable to check for changes in the status in the first 500~$\mu$s. ATTENTION: if you are in 16 bit mode and you are applying online rate corrections, as now the exptime is generated by the trigger, you might not have correct rate corrections. If you know what the exposure time is in the gating signal, then you can set the {\tt{exptime}} once and the rate corrections will be correct. In 32 bit mode, it does not matter as the rate corrections depends on the {\tt{subexptime}} which is software set independently from the gate exptime.

ATTENTION: From release 4.1.1 with the {\tt{trigger}} option it is possible to have software triggers as a debugging tool (instead of the hardware trigger signal. One should start the acquisition (with the blocking {\tt{sls\_detector\_acquire}} if wanted and with another client one can send the softare trigger {\tt{sls\_detector\_put status trigger}}. This option allows for example to perform a motor scan (moving a motor in between single images) and still writing all images to the same file.
When using 32-bit mode, by default the acquisition ends the last complete subframe that was started when still the acquisition time was valid. This has been chosen as many people wants to know the exact acquisition time for when the detector was taking data and also, if {\tt{ratecorr}} are active, the last subframe will be correctly corrected, while otherwise it will be corrected with a wrong subdeadtime.
However, from 4.1.0, in gating mode, an option to immediately terminate the subframe when the gate signal goes down it is implemented to stop the acquisition at the same time. This option is {\tt{./sls\_detector\_put interruptsubframe 1}} while the default option is {\tt{./sls\_detector\_put interruptsubframe 0}}.