BEFORE you start - Set MTU - 1700 or 9000 on the distributed switch on vCenter > Network section
-
Download the NSX-T Manager from VMWare portal
-
Ensure the ESXi hosts are upgraded to the 6.7 U3 (use upgrade manager to upgrade the hosts)
-
Create a distributed switch
dvSwitch
and assign thevmnic1
(Use vcenter-terraform for HOMELAB) for all the hosts that are part of this switch -
Import the NSX-T manager using govc (Use ../deploy-nsx/govc-deploy)
- Create a file
govc-env
and paste the following contents into it
export GOVC_INSECURE=1 export GOVC_URL=vcenter.homelab.io export [email protected] export GOVC_PASSWORD=VMware1! export GOVC_DATACENTER=HOMELAB export GOVC_DATASTORE=COMMON_STORAGE export GOVC_NETWORK="VM Network" export GOVC_RESOURCE_POOL=/HOMELAB/host/MANAGEMENT/Resources/NSX_RP export GOVC_HOST=esxi-1.homelab.io
- Create a file called
nsx-appliance.json
with the following contents
{ "Deployment": "medium", "DiskProvisioning": "flat", "IPAllocationPolicy": "dhcpPolicy", "IPProtocol": "IPv4", "PropertyMapping": [ { "Key": "nsx_passwd_0", "Value": "VMware1!" }, { "Key": "nsx_cli_passwd_0", "Value": "VMware1!" }, { "Key": "nsx_cli_audit_passwd_0", "Value": "VMware1!" }, { "Key": "nsx_cli_username", "Value": "admin" }, { "Key": "nsx_cli_audit_username", "Value": "audit" }, { "Key": "extraPara", "Value": "" }, { "Key": "nsx_hostname", "Value": "nsx.homelab.io" }, { "Key": "nsx_role", "Value": "NSX Manager" }, { "Key": "nsx_gateway_0", "Value": "172.16.0.1" }, { "Key": "nsx_ip_0", "Value": "172.16.0.61" }, { "Key": "nsx_netmask_0", "Value": "255.255.254.0" }, { "Key": "nsx_dns1_0", "Value": "172.16.0.30,172.16.0.31" }, { "Key": "nsx_domain_0", "Value": "" }, { "Key": "nsx_ntp_0", "Value": "ntp.homelab.io" }, { "Key": "nsx_isSSHEnabled", "Value": "True" }, { "Key": "nsx_allowSSHRootLogin", "Value": "True" }, { "Key": "mpIp", "Value": "" }, { "Key": "mpToken", "Value": "" }, { "Key": "mpThumbprint", "Value": "" }, { "Key": "mpNodeId", "Value": "" }, { "Key": "mpClusterId", "Value": "" } ], "NetworkMapping": [ { "Name": "Network 1", "Network": "VM Network" } ], "MarkAsTemplate": false, "PowerOn": true, "InjectOvfEnv": false, "WaitForIP": false, "Name": "nsx-manager" }
- Source the
govc-env
file and then executegovc import.ova -options=nsx-appliance.json nsx-unified-appliance-3.0.2.0.0.16887203.ova
- Create a file
-
Once the NSX manager is up and running, navigate to the nsx manager console and login
-
Generate a CSR and self signed certificate, navigate to System > Certificates
-
Update the nsx manager certificate using the
curl
commandcurl -u "admin:VMware1!" -X POST --insecure "https://nsx.homelab.io/api/v1/node/services/http?action=apply_certificate&certificate_id=52bba154-3803-4e8e-b732-6a8c191a370b"
-
Add the nsx manager license
-
Update the Gloabl MTU on NSX-Manager to
9000
, System > Fabric > Settings -
Register compute manager
-
In NSX-T 3.x, NSX Manager and NSX controller are bundled together
-
Create 2 transport zones
NAME SWITCH switch-overlay
switch-overlay
switch-vlan
switch-vlan
-
Create a Profile
- Name:
nsx-esxi-uplink-hostswitch-profile
- Teamings Name:
Default Teaming
| Active Uplinks:uplinks-1
- Transport VLAN:
3000
- MTU:
BLANK
- Name:
-
Create a
TEP-IP-POOL
by going to Networking > IP Address Pools > IP Address PoolsTEP-IP-POOL
|172.16.100.1-172.16.100.254
|172.16.100.0/24
(CIDR)
-
Create the Load Balancer Active Monitors, Networking > Load Balancing > Monitors > Add Active Monitors
TYPE NAME MONITORING PORT TCP
ROUTERS
8080 TCP
DIEGO_BRAINS
2222 TCP
ISTIO_ROUTERS
8080 TCP
TKGI_API
9021 -
Create the Transport Node Profile by clicking on Fabric > Profiles > Transport Node Profiles
- Name:
host-transport-node-profile
- Type
N-VDS
- Mode: Standard
- Name:
switch-overlay
- Transport Zone:
switch-overlay
- Uplink Profile:
nsx-esxi-uplink-hostswitch-profile
- IP Assignment:
Use IP Pool
- IP Pool:
TEP-IP-POOL
- Uplinks:
uplink-1 (active): vmnic1
- Name:
OR
-
Create the Transport Node Profile by clicking on Fabric > Profiles > Transport Node Profiles
- Name:
host-transport-node-profile
- Type
VDS
- Name:
vCenter
dvSwitch
- Transport Zone:
switch-overlay
switch-vlan
- Uplink Profile:
nsx-esxi-uplink-hostswitch-profile
- IP Assignment:
Use IP Pool
- IP Pool:
TEP-IP-POOL
- Uplinks:
uplink-1 (active): uplink1
- Name:
-
Click on System > Fabric > Nodes > Edge Transport Nodes > Add Edge VM
- Create the edge node, of
large
form factor. Load balancers need minimum oflarge
edge node
- Name it
nsx-edge
with the hostnamensx-edge.homelab.io
- Use password
VMware1!
- Allow SSH Login & Allow Root SSH Login -
true
- Compute Manager:
vCenter
- Cluster:
WORKLOAD
- Resource Pool:
NSX
- Datastore:
MANAGEMENT_STORAGE
- Assign a static IP to the edge
172.16.0.62/22
and gateway is172.16.0.1
- Select the network as
VM Network
for all the 4 interfaces
- Assign the overlay transport zone (East-West)
- Edge Switch Name:
switch-overlay
- Transport Zone:
switch-overlay
- Uplink Profile:
nsx-edge-single-nic-uplink-profile
- IP Assignment:
Use IP Pool
- IP Pool:
TEP-IP-POOL
- Uplinks:
uplink-1 (active)
| Virtual NICs:fp-eth0
|EDGE-VTEP-PG
- Physical NICs:
vmnic1
-uplink-1
- Edge Switch Name:
- Assign the vlan transport zone (North-South)
- Edge Switch Name:
switch-vlan
- Transport Zone:
switch-vlan
- Uplink Profile:
nsx-edge-single-nic-uplink-profile
- Uplinks:
uplink-1 (active)
| Virtual NICs:fp-eth1
|EDGE-UPLINK-PG
- Physical NICs:
vmnic1
-uplink-1
- Edge Switch Name:
- Create the edge node, of
-
Create a new edge cluster
edge-cluster
-
Click on System > Fabric > Nodes > Host Transport Nodes > vCenter > WORKLOAD
Configure NSX
and select thehost-transport-node-profile
-
Final view of vSphere Network after terraform
NOTE: choose vmnic1
as vmnic0
is already assigned to the distributed switch common_dvPortGroup
Validate this setting on nsx-edge
before moving on
N-VDS Type | Uplink Profile | IP Allocation | Virtual Nics |
---|---|---|---|
nsx-overlay-transportzone |
nsx-edge-single-nic-uplink-profile | Use IP Pool (TEP-IP-POOL) | fp-eth0 |
nsx-vlan-transportzone |
nsx-edge-single-nic-uplink-profile | - | fp-eth1 |
-
Create Tier-0 Gateway by clicking on Networking > Tier-0 Gateway > Add Gateway
- Name:
ROUTER-T0
- HA Mode:
Active Standby
- Edge Cluster:
edge-cluster
- Failover Mode:
Non-Preemptive
- Name:
-
Create Tier-1 Gateway by clicking on Networking > Tier-1 Gateway > Add TIER-1 Gateway
INFRASTRUCTURE-T1
and enable Router-Advertisement for:- All Static Routes
- All Connected Segments & Service Ports
- All LB VIP Routes
-
Create Tier-1 Gateway by clicking on Networking > Tier-1 Gateway > Add TIER-1 Gateway
DEPLOYMENT-T1
and enable Router-Advertisement for:- All Static Routes
- All Connected Segments & Service Ports
- All LB VIP Routes
-
Create Tier-1 Gateway by clicking on Networking > Tier-1 Gateway > Add TIER-1 Gateway
SERVICES-T1
and enable Router-Advertisement for:- All Static Routes
- All Connected Segments & Service Ports
- All LB VIP Routes
-
Create Segments (logical switches), Networking > Segments
Name | Uplink & Type | Subnet | Transport Zone | VLAN |
---|---|---|---|---|
INFRASTRUCTURE | INFRASTRUCTURE-T1 |
192.168.10.1/26 |
switch-overlay |
- |
DEPLOYMENT | DEPLOYMENT-T1 |
192.168.12.1/23 |
switch-overlay |
- |
SERVICES | SERVICES-T1 |
192.168.14.1/23 |
switch-overlay |
- |
UPLINKS | - | - | switch-vlan |
0 |
-
Select the
ROUTER-T0
and then Edit > Interfaces > External and Service Interfaces > Configuration > Router Ports > Add- Name:
UPLINK-TO-PYHSICAL
- MTU:
1600
- Transport Node:
edge-tn
- Logical Switch:
UPLINKS
- Logical Switch Port:
Attach to new switch port
- IP Address/mask:
172.16.0.28/23
- Name:
-
Select the
ROUTER-T0
and then click Edit > Routing > Static Routes > Add- Network:
0.0.0.0/0
- Next Hop:
172.16.0.1
- Distance:
1
- Network:
-
Configuring NAT rules, select the Gateway
ROUTER-T0
and then click Add NAT Rule
Rule Type | Source | Destination | Applied To |
---|---|---|---|
SNAT | 192.168.0.0/16 | 172.16.0.29 | UPLINK-TO-PYHSICAL |
DNAT | 172.16.0.30 | 192.168.10.9 (For testing only) | UPLINK-TO-PYHSICAL |
- Create a load balancer, Networking > Load Balancing > Add
pcf-lb
|small
- Attach the load balancer to the T1 router
INFRASTRUCTURE-T1
- Create Server Pools and Virtual Servers
Virtual Server Name | IP | Port | Server Pool Name | Server Pool Monitoring |
---|---|---|---|---|
OpsManagerVirtualServer | 172.16.0.30 | 22-8443 | OpsManagerServerPool | TCP port 443 |
RoutersVirtualServer | 172.16.0.31 | 443 | RouterServerPool | TCP port 443 |
DiegoBrainsVirtualServer | 172.16.0.32 | 2222 | DiegoBrainServerPool | TCP port 2222 |
- Attach the load balancer to the Virtual Servers
-
Create a New IP Pool for
Orgs
, those are created upon PAS deployment. Navigate to Networking > IPAM and click Add >pcf-ip-block
-192.168.32.0/19
-
Create a external SNAT IP Pool for the external networking. Go to Groups > IP Pools > Add
pcf-floating-ip-pool
|172.16.0.50 - 172.16.0.70
|172.16.0.0/23
(CIDR)
NOTE: On the edgerouter X, define a static routing for 172.16.30.0/24 to route to 172.16.0.31 (NSX-T edge router IP). 172.16.30.0/24
is a transient network used to relay traffic from one edge router to another