Añadir información de documentación en README #55

Open
wants to merge 1 commit into
base: master
Choose a base branch
from
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
117 changes: 49 additions & 68 deletions README.md
Original file line number Diff line number Diff line change
@@ -1,89 +1,70 @@
# ApolloVentilator

Information: Checkout our [wiki](https://github.com/makespacemadrid/ApolloVentilator/wiki)

## Getting started
ApolloVentillator es un proyecto colaborativo para la construcción de equipos de respiración asistida libres que surge a raíz de la crisis del COVID-19. Su misión es apoyar a los equipos sanitarios aportando respiradores en momentos de escasez de estos dispositivos.

### Linux
Los objetivos de este proyecto son:

- Durabilidad. Debe permitir ser usado como apoyo a la respiración del paciente de manera continuada durante al menos 2 semanas.
- Seguridad. Debe cumplir los requisitos de calidad necesarios para poder ser utilizado de forma segura.
- Replicabilidad. Debe poder ser replicados con facilidad.Los materiales deben ser fáciles de conseguir y su montaje debe ser sencillo y rápido.

Al ser un proyecto en desarrollo continuo gran parte de la información se puede encontrar en nuestra [wiki](https://github.com/makespacemadrid/ApolloVentilator/wiki).

El código se libera bajo la GPL 3. [Ver [LICENSE](LICENSE)]


## ¿Como colaborar?

Actualmente nos encontramos agregando información en la wiki y trabajando en un prototipo.

Puedes encontrar las notas de colaboración en [COLLABORATION](man/COLLABORATION.md).


## Requerimientos

### Software

#### Linux

```
$ apt-get install libcairo2-dev libgirepository1.0-dev python3-cairo-dev
```

### Mac
#### Mac

```
$ brew install pygobject3 gtk+3 libnotify
```

### App (Python 3)
### Firmware
> TO DO: Requerimientos para cargar firmware (Dispositivo usado, entorno, etc...)

From ```./gui```
### Hardware
> TO DO Kicad, FreeCAD

Install system dependencies (Debian-based):
## Puntos de entrada

```
#### Software

La aplicación está escrita en python3 utilizando el framework Qt5.

Para lanzar la aplicación es necesario contar con las dependencias indicadas en el fichero
`gui/requirements.txt`.


```shell script
$ cd gui
$ pip install -r requirements.txt
$ ./main.py
```

## Requirements:
2 ventilators mode
* Pressure Regulated Volume Controlled (PCV): set pressure delivered during period of inspiration. The voume measured is shown as data on display.
* Volume Regulated Pressure controlled (VCV): The tidal volume is set and it adapts the pressure to the lowest. Here the important data are: tidal volume, upper alarm and lower current volume. Useful parameters: tidal volume, respiratory rate. There is a limit pressure and during inspiration period.

If patient stops breathing, there is a failsafe that set to mandatory breathing when it's detected.

During inspiration:

* Inspiration pressure: The plateau pressure is adjusted to volume hard limit (32 cmH2O by default, and could increate to 70cmH2O)
* Peak pressure: 2cmH2O greater than plateau.
* VCV pressure limit (15-40cm2 with increments of 5)
* Failsafe valve that opens always at 80cmH20 (or lower)

* PEEP: 5-10 with increments of 5. The circuit must be pressured.
* IE ratio: 1:1, 1:2, 1:3
* Respiratory rate: 10-30 bpm with increments of 2.
* Tidal volume: 40ml +-10, 350 +-50, 250-600 +-50,up to 8000.
* Weight body and volume calculated based on 6ml/kg.


## Alarms

* Gas failure
* Electricity failure
* Machine switched off
* Inspiration pressure exceeded
* Inspiration pressure not achieved
* PEEP pressure not achieved
* Tidal volume not achieved
* Tidal volume exceeded
* Resistance: peak pressure - plateau pressure > 2cmH2O
* Compliance
* Volume Leakage

## Monitoring
### Settings
* Tidal volume
* Frequency
* PEEP
* FI02
* Ventilation Mode

### Current status
* Tidal volume
* Breathing rate
* PEEP
* Plateau pressure
* FI02

The normal healthy O2 consuption is 250mL/min, and could be increased until, for example 500 mL/min in a sepsis.

### Parallel measures

* Presión arteria
* Frecuencia cardiaca
* ECG
* Nivel de sedación
* Posicion del tubo e inflado del neumotaponamiento
* Intercambio gaseoso (pulsiometria SO2), capnografía y gasometrías arteriales periodicas para obtener los **índices de oxigenación** (clave para evaluar la desintubación del paciente).
#### Firmware

> TO DO: Carga del firmware en dispositivo y funcionamiento

## Modos de funcionamiento

- Firmware: [Ver man/firmware.md](man/firmware.md)

- Software y Monitorización: [Ver man/software.md](man/software.md)
File renamed without changes
5 changes: 5 additions & 0 deletions COLLABORATION.md → man/collaboration.md
Original file line number Diff line number Diff line change
Expand Up @@ -27,6 +27,10 @@
Issue
- Funcionamiento del bucle de draw en interfaz QT

Authors
- @foo
- @bar

Objetivo
- Visualizar correctamente una gráfica que pinte valores que se obtienen dinámicamente (puerto serie o tty emulado).

Expand All @@ -45,6 +49,7 @@ Changelog
> También se puede hacer en la PR

- En la PR, si se utiliza la opción de Squash y --no-ff se puede mergear el commit sin añadir commits de merge al historico.
> Opción Rebase and merge en el boton de acción de la PR

4. Documentación

Expand Down
36 changes: 36 additions & 0 deletions man/firmware.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,36 @@
# Firmware ApolloVentilator

## Requirements:
2 ventilators mode
* Pressure Regulated Volume Controlled (PCV): set pressure delivered during period of inspiration. The voume measured is shown as data on display.
* Volume Regulated Pressure controlled (VCV): The tidal volume is set and it adapts the pressure to the lowest. Here the important data are: tidal volume, upper alarm and lower current volume. Useful parameters: tidal volume, respiratory rate. There is a limit pressure and during inspiration period.

If patient stops breathing, there is a failsafe that set to mandatory breathing when it's detected.

During inspiration:

* Inspiration pressure: The plateau pressure is adjusted to volume hard limit (32 cmH2O by default, and could increate to 70cmH2O)
* Peak pressure: 2cmH2O greater than plateau.
* VCV pressure limit (15-40cm2 with increments of 5)
* Failsafe valve that opens always at 80cmH20 (or lower)

* PEEP: 5-10 with increments of 5. The circuit must be pressured.
* IE ratio: 1:1, 1:2, 1:3
* Respiratory rate: 10-30 bpm with increments of 2.
* Tidal volume: 40ml +-10, 350 +-50, 250-600 +-50,up to 8000.
* Weight body and volume calculated based on 6ml/kg.


## Alarms

* Gas failure
* Electricity failure
* Machine switched off
* Inspiration pressure exceeded
* Inspiration pressure not achieved
* PEEP pressure not achieved
* Tidal volume not achieved
* Tidal volume exceeded
* Resistance: peak pressure - plateau pressure > 2cmH2O
* Compliance
* Volume Leakage
File renamed without changes.
34 changes: 34 additions & 0 deletions man/software.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,34 @@
# Software Monitorización ApolloVentilator

## Elementos

- Clase + CLI: Conversión y tratamiento de mensajes desde puerto serie.
- Interfaz: Implementa la visualización de datos, la configuración del sistema y el control
de las alarmas.

## Monitoring

### Settings
* Tidal volume
* Frequency
* PEEP
* FI02
* Ventilation Mode

### Current status
* Tidal volume
* Breathing rate
* PEEP
* Plateau pressure
* FI02

The normal healthy O2 consuption is 250mL/min, and could be increased until, for example 500 mL/min in a sepsis.

### Parallel measures

* Presión arteria
* Frecuencia cardiaca
* ECG
* Nivel de sedación
* Posicion del tubo e inflado del neumotaponamiento
* Intercambio gaseoso (pulsiometria SO2), capnografía y gasometrías arteriales periodicas para obtener los **índices de oxigenación** (clave para evaluar la desintubación del paciente).