When trying to configure my Vaillant VRC630 I've found that several values are not configurable in hcmode, hwcmode and mcmode.
So I've made several tests on how to achieve writing to SetMode, SetTempDesired, SetTempDesiredLow, etc.
Here is my result. I'm using ebusd with my changed configuration now for 5 months and have no issues.
So I'd suggest to take my changes over in your official repository if you like.

#potential last byte: currentmode,s,UCH,0=off;1=standby;2=heat;3=water,,
r,,Status01,Vorlauftemperatur/Rücklauftemperatur/Aussentemperatur/WW Temperatur/Speichertemperatur/Pumpenstatus,,,,01,,,temp1;temp1;temp2;temp1;temp1;pumpstate,,,
r,,Status02,Betriebsart/Maximaltemperatur/ReglerCurrentTEMP/Maximaltemperatur/ReglerCurrentTemp,,,,02,,,hwcmode;temp0;temp1;temp0;temp1,,,
r,,Status,Status,,,,03,,,temp;press;press;hcmode2;HEX,,,

Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

why did you remove this?


# HC Betriebsart2,,,,,,,,,,,,,
*r,,,,,,"B511",,,,,,,
*uw,,,,,,"B510",,,,,,,
uw,,SetMode,Betriebsart,,,,00,,,hcmode,,,,flowtempdesired,,temp1,,,,hwctempdesired,,temp1,,,,hwcflowtempdesired,,temp0,,,,,,IGN:1,,,,disablehc,,BI0,,,,disablehwctapping,,BI1,,,,disablehwcload,,BI2,,,,,,IGN:1,,,,remoteControlHcPump,,BI0,,,,releaseBackup,,BI1,,,,releaseCooling,,BI2,,,,
uw,,SetOperatingMode,Betriebsart,,,,00,,,hcmode,,,,flowtempdesired,,temp1,,,,hwctempdesired,,temp1,,,,hwcflowtempdesired,,temp0,,,,,,IGN:1,,,,disablehc,,BI0,,,,disablehwctapping,,BI1,,,,disablehwcload,,BI2,,,,,,IGN:1,,,,remoteControlHcPump,,BI0,,,,releaseBackup,,BI1,,,,releaseCooling,,BI2,,,,
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

why does this have to be renamed?

r,,Status16,Aussentemperatur,,,,16,,,temp,,,
w,,SetTempDesired,Solltemperatur setzen,,,,01,,,temp0,,,
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

many of those new items don't work on my EHP, so I guess these would have to go to a new hcmode2.inc or so and then included additionally from the circuits supporting it

@john30
Copy link
Owner

john30 commented Jan 14, 2024

number of lines in de/en files is different and supposed to be equal

john30 added a commit that referenced this pull request Dec 28, 2024
…lds and add found fine granular setmaxpreheating message
@john30
Copy link
Owner

john30 commented Dec 28, 2024

partial of mcmode changes reworked+merged in 998470f

@john30
Copy link
Owner

john30 commented Dec 29, 2024

please check the next generated csvs with ebusd 24.1 (or current source) as described there or by using a local clone of https://github.com/eBUS/ebus.github.io and using the "next" folder in there