Notifications
You must be signed in to change notification settings - Fork 218
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #3122 from davidraker/docker_test_updates
Updates for tests run on Docker before 9.0 release.
- Loading branch information
Showing
9 changed files
with
146 additions
and
14 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,2 +1,2 @@ | ||
openleadr==0.5.27 | ||
cryptography==37.0.4 | ||
openleadr==0.5.30 | ||
cryptography==37.0.4 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -48,4 +48,4 @@ | |
- addressing: offset | ||
endian: big | ||
file: battery_meter.csv | ||
name: battery_meter | ||
name: battery_meter |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
120 changes: 120 additions & 0 deletions
120
.../PlatformDriverAgent/platform_driver/interfaces/modbus_tk/tests/test_driver_demo_board.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,120 @@ | ||
import os | ||
|
||
import gevent | ||
import pytest | ||
from volttron.platform.agent.known_identities import CONFIGURATION_STORE, PLATFORM_DRIVER | ||
from volttron.platform import jsonapi | ||
from volttrontesting.utils.platformwrapper import PlatformWrapper | ||
|
||
MODBUS_TEST_IP = "MODBUS_TEST_IP" | ||
|
||
# apply skipif to all tests | ||
skip_msg = f"Env var {MODBUS_TEST_IP} not set. Please set the env var to the proper IP to run this integration test." | ||
pytestmark = pytest.mark.skipif(os.environ.get(MODBUS_TEST_IP) is None, reason=skip_msg) | ||
|
||
|
||
def test_get_point(publish_agent): | ||
registers = ["SupplyTemp", "ReturnTemp", "OutsideTemp"] | ||
for point_name in registers: | ||
point_val = publish_agent.vip.rpc.call(PLATFORM_DRIVER, "get_point", "modbustk", | ||
point_name).get(timeout=10) | ||
print(f"Point: {point_name} has point value of {point_val}") | ||
assert isinstance(point_val, int) | ||
|
||
|
||
def test_set_point(publish_agent): | ||
point_name = "SecondStageCoolingDemandSetPoint" | ||
point_val = 42 | ||
publish_agent.vip.rpc.call(PLATFORM_DRIVER, "set_point", "modbustk", point_name, | ||
point_val).get(timeout=10) | ||
assert publish_agent.vip.rpc.call(PLATFORM_DRIVER, "get_point", "modbustk", | ||
point_name).get(timeout=10) == point_val | ||
|
||
|
||
@pytest.fixture(scope="module") | ||
def publish_agent(volttron_instance: PlatformWrapper): | ||
assert volttron_instance.is_running() | ||
vi = volttron_instance | ||
assert vi is not None | ||
assert vi.is_running() | ||
|
||
config = { | ||
"driver_scrape_interval": 0.05, | ||
"publish_breadth_first_all": "false", | ||
"publish_depth_first": "false", | ||
"publish_breadth_first": "false" | ||
} | ||
puid = vi.install_agent(agent_dir=Path(__file__).parent.parent.parent.parent.parent.absolute().resolve(), | ||
config_file=config, | ||
start=False, | ||
vip_identity=PLATFORM_DRIVER) | ||
assert puid is not None | ||
gevent.sleep(1) | ||
assert vi.start_agent(puid) | ||
assert vi.is_agent_running(puid) | ||
|
||
# create the publish agent | ||
publish_agent = volttron_instance.build_agent() | ||
assert publish_agent.core.identity | ||
gevent.sleep(1) | ||
|
||
capabilities = {"edit_config_store": {"identity": PLATFORM_DRIVER}} | ||
volttron_instance.add_capabilities(publish_agent.core.publickey, capabilities) | ||
gevent.sleep(1) | ||
|
||
# Add Modbus Driver TK registry map to Platform Driver | ||
registry_config_string = """Register Name,Address,Type,Units,Writable | ||
SupplyTemp,0,uint16,degC,FALSE | ||
ReturnTemp,1,uint16,degC,FALSE | ||
OutsideTemp,2,uint16,degC,FALSE | ||
SecondStageCoolingDemandSetPoint,14,uint16,degC,TRUE""" | ||
publish_agent.vip.rpc.call(CONFIGURATION_STORE, | ||
"manage_store", | ||
PLATFORM_DRIVER, | ||
"m2000_rtu_TK_map.csv", | ||
registry_config_string, | ||
config_type="csv").get(timeout=10) | ||
|
||
# Add Modbus Driver registry to Platform Driver | ||
registry_config_string = """Register Name,Volttron Point Name | ||
SupplyTemp,SupplyTemp | ||
ReturnTemp,ReturnTemp | ||
OutsideTemp,OutsideTemp | ||
SecondStageCoolingDemandSetPoint,SecondStageCoolingDemandSetPoint""" | ||
publish_agent.vip.rpc.call(CONFIGURATION_STORE, | ||
"manage_store", | ||
PLATFORM_DRIVER, | ||
"m2000_rtu_TK.csv", | ||
registry_config_string, | ||
config_type="csv").get(timeout=10) | ||
|
||
# Add Modbus Driver config to Platform Driver | ||
device_address = os.environ.get(MODBUS_TEST_IP) | ||
driver_config = { | ||
"driver_config": { | ||
"device_address": device_address, | ||
"slave_id": 8, | ||
"port": 502, | ||
"register_map": "config://m2000_rtu_TK_map.csv" | ||
}, | ||
"campus": "PNNL", | ||
"building": "DEMO", | ||
"unit": "M2000", | ||
"driver_type": "modbus_tk", | ||
"registry_config": "config://m2000_rtu_TK.csv", | ||
"interval": 60, | ||
"timezone": "Pacific", | ||
"heart_beat_point": "heartbeat" | ||
} | ||
|
||
publish_agent.vip.rpc.call(CONFIGURATION_STORE, | ||
"manage_store", | ||
PLATFORM_DRIVER, | ||
"devices/modbustk", | ||
jsonapi.dumps(driver_config), | ||
config_type='json').get(timeout=10) | ||
|
||
yield publish_agent | ||
|
||
volttron_instance.stop_agent(puid) | ||
publish_agent.core.stop() |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters