Notifications
You must be signed in to change notification settings - Fork 5
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Breaking down what the data looks like in the sorted csv files
- Loading branch information
Showing
1 changed file
with
34 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,34 @@ | ||
## Data Breakdown | ||
|
||
py_packages/vis_buses/bus_1/!3J0018_ProfileData_20170920082828.csv | ||
|
||
This is the first csv of bus 1, data from bus 1's first visit | ||
|
||
Each visit will have a data breakdown of the following: | ||
|
||
#### <Battery Current (A)> | ||
|
||
Breaks down the amount of time (in seconds) that the battery was experiencing that value of current (in Amps). In bins of 10 Amps going from -350A to 350+A. This data was collected over 80985877 seconds which is 937.3 days worth of data. | ||
|
||
#### <Battery Voltage (V)> | ||
Breaks down the amount of time (in seconds) that the battery spent at a corresponding Voltage (in Volts) . In bins of 10 Volts going from 450V to 750+V. This data was collected over 80985877 seconds which is 937.3 days worth of data. | ||
|
||
#### <Power (kW)> | ||
Breaks down the amount of time (in seconds) that the battery spent at a corresponding Power (in kW) . In bins of 10 kW going from -200kW to 200+kW. This data was collected over 80985877 seconds which is 937.3 days worth of data. | ||
|
||
The data is then broken down into modules 1 through 16 | ||
Each module has 12 cells. | ||
|
||
#### <Cell Voltages (V)> | ||
Breaks down the amount of time (in seconds) that each cell 1-12 of that module spent at a corresponding voltage (in Volts). In bins of 10 kW going from 2V to 4+V. | ||
|
||
#### <Cell Balancers> | ||
Shows the amount of time (in seconds) that the cells of the module were turned on and off to maintain even usage of each cell in the module. | ||
|
||
#### <Module Temperatures (deg C)> | ||
Shows the time (in seconds) that the module spent at different temperatures (in degrees Celsius). In bins of 5C going from -40C to 80+C. | ||
|
||
#### <Module Voltages (V)> | ||
Breaks down the amount of time (in seconds) that the module spent at a corresponding Voltage (in Volts) . In bins of 2.4Volts going from 24V to 48+V. | ||
|
||
|