OpenStudio-ERI v1.3.0
OpenStudio-ERI version 1.3.0 has been released. The OpenStudio-ERI workflow calculates an Energy Rating Index (ERI) using the Department of Energy's OpenStudio/EnergyPlus building simulation platform. The open-source workflow is intended to be used by residential software tools that provide a HPXML building description file.
Two packages are available, a minimal zip with a handful of weather files and full zip with all US TMY3 weather files. OpenStudio-ERI v1.3.0 uses OpenStudio v3.3.0, EnergyPlus v9.6.0, and a proposed HPXML v4.0. Please visit the OpenStudio-ERI v1.3.0 documentation for instructions on how to get started, how to connect software tools to the workflow, etc.
New Features
- Updates to OpenStudio 3.3.0/EnergyPlus 9.6.0.
- Breaking change: HVAC grading inputs
FanPowerNotTested
,AirflowNotTested
, andChargeNotTested
are no longer accepted. - Breaking change: Replaces "Unmet Load" outputs with "Unmet Hours".
- Breaking change: Renames "Load: Heating" and "Peak Load: Heating" (and Cooling) outputs to include "Delivered".
- Breaking change: Any heat pump backup heating requires
HeatPump/BackupType="integrated"
to be specified. - Breaking change: HPXML schema version must now be '4.0' (proposed).
- Moves
FoundationWall/Insulation/Layer/extension/DistanceToTopOfInsulation
toFoundationWall/Insulation/Layer/DistanceToTopOfInsulation
. - Moves
FoundationWall/Insulation/Layer/extension/DistanceToBottomOfInsulation
toFoundationWall/Insulation/Layer/DistanceToBottomOfInsulation
. - Moves
Slab/PerimeterInsulationDepth
toSlab/PerimeterInsulation/Layer/InsulationDepth
. - Moves
Slab/UnderSlabInsulationWidth
toSlab/UnderSlabInsulation/Layer/InsulationWidth
. - Moves
Slab/UnderSlabInsulationSpansEntireSlab
toSlab/UnderSlabInsulation/Layer/InsulationSpansEntireSlab
.
- Moves
- Allows modeling PTAC and PTHP HVAC systems.
- Allows additional fuel types for generators.
- Allows non-zero refrigerant charge defect ratios for ground source heat pumps.
- Allows CEER (Combined Energy Efficiency Ratio) efficiency unit for room AC.
- Allows specifying the foundation wall type (e.g., solid concrete, concrete block, wood, etc.).
- Removes error-check for number of bedrooms based on conditioned floor area, per RESNET guidance.
- Introduces a small amount of infiltration for unvented spaces.
ConditionedBuildingVolume
input is no longer needed (and removes error-check forInfiltrationVolume
relative to it).- Improves consistency of installation quality calculations for two/variable-speed air source heat pumps and ground source heat pumps.
Bugfixes
- Improves ground reflectance for window interior shading.
- Improves HVAC fan power for central forced air systems.
- Fixes mechanical ventilation compartmentalization area calculation for SFA/MF homes with surfaces with InteriorAdjacentTo==ExteriorAdjacentTo.
- Negative
DistanceToTopOfInsulation
values are now disallowed. - Fixes workflow errors if a
VentilationFan
has zero airflow rate or zero hours of operation. - Fixes heating/cooling seasons (used for e.g. summer vs winter window shading) for the southern hemisphere.
- Relaxes
Overhangs
DistanceToBottomOfWindow vs DistanceToBottomOfWindow validation when Depth is zero. - Fixes possibility of "Construction R-value ... does not match Assembly R-value" error.