Envelope - Rule 5-5

Schema Version 0.0.23
Primary Rule: False Rule ID: 5-5
Rule Description: Baseline below-grade walls shall conform with assemblies detailed in Appendix A Concrete block, A4).
Appendix G Section: Section G3.1-5(b) Building Envelope Modeling Requirements for the Baseline building
Appendix G Section Reference: None

Applicability: All required data elements exist for B_RMD
Applicability Checks:

  1. Surfaces that are a regulated below-grade wall

Evaluation Context: Each Data Element
Data Lookup: None
Function Call:

  1. get_surface_conditioning_category()
  2. get_opaque_surface_type()

Rule Logic:

  • Get surface conditioning category dictionary for B_RMD: scc_dictionary_b = get_surface_conditioning_category(B_RMD)

  • For each building segment in the Baseline model: for building_segment_b in B_RMD.building.building_segments:

    • For each zone in building segment: for zone_b in building_segment_b.zones:

      • For each surface in zone: for surface_b in zone_b.surfaces:

        Rule Assertion:

        Case 1: Surface is a below-grade wall and is regulated; outcome is UNDETERMINED: if ( ( get_opaque_surface_type(surface_b) == "BELOW-GRADE WALL" ) AND ( scc_dictionary_b[surface_b.id] != UNREGULATED ) ): outcome = "UNDETERMINED" and raise_message "<Insert surface_b.id> is a regulated below-grade wall surface. Conduct a manual check to confirm that Baseline below-grade wall assemblies conform with assemblies detailed in Appendix A."

        Case 2: Else; outcome is NOT_APPLICABLE: else: outcome = NOT_APPLICABLE

Notes:

  1. Update Rule ID from 5-7 to 5-5 on 10/26/2023