Envelope - Rule 5-24

Rule ID: 5-24
Rule Description: If skylight area in the proposed design is 3% or less of the roof surface, the skylight area in baseline shall be equal to that in the proposed design.
Rule Assertion: B-RMD total (subsurface.glazed_area+subsurface.opaque_area) = expected value
Appendix G Section: Section G3.1-5(e) Building Envelope Modeling Requirements for the Baseline building
Appendix G Section Reference: None

Applicability: All required data elements exist for B_RMD Applicability Checks:

  1. the skylight area in the proposed design is 3% or less.

Manual Check: None
Evaluation Context: Each Data Element
Data Lookup: None
Function Call:

  1. get_building_segment_skylight_roof_areas()
  2. match_data_element()

Rule Logic:

  • Get building skylight roof areas dictionary for B_RMD: skylight_roof_areas_dictionary_b = get_building_segment_skylight_roof_areas(B_RMD)

  • Get building skylight roof areas dictionary for P_RMD: skylight_roof_areas_dictionary_p = get_building_segment_skylight_roof_areas(P_RMD)

  • For each building segment in B_RMD: for building_segment_b in B_RMD.building.building_segments:

    • Calculate skylight roof ratio for building segment: skylight_roof_ratio_b = skylight_roof_areas_dictionary_b[building_segment_b.id][total_skylight_area] / skylight_roof_areas_dictionary_b[building_segment_b.id][total_envelope_roof_area]

    • Get matching building segment in P_RMD: building_segment_p = match_data_element(P_RMD, BuildingSegments, building_segment_b.id)

      • Calculate skylight roof ratio of all building_segments in P_RMD: skylight_roof_ratio_p = sum(skylight_roof_building_segment_p[total_skylight_area] for skylight_roof_building_segment_p in skylight_roof_areas_dictionary_b) / sum(skylight_roof_building_segment_p[total_envelope_roof_area] for skylight_roof_building_segment_p in skylight_roof_areas_dictionary_b)

      • Check if skylight roof ratio in P_RMD is 3% or less: if skylight_roof_ratio_p <= 0.03:

      • if skylight roof ratio in P_RMD is greater than 3%, Rule is not applicable: else: NOT_APPLICABLE

        Rule Assertion:

        • Case 1: For each building segment in B_RMD, the skylight to roof ratio is equal to that in P_RMD: if skylight_roof_ratio_b == skylight_roof_ratio_p: PASS

        • Case 2: Else: Else: FAIL

Notes:

  1. Update Rule ID from 5-34 to 5-24 on 10/26/2023

**Back