Transformers - Rule 15-2

Rule ID: 15-2
Rule Description: Number of transformers modeled in User RMR and Proposed RMR are the same
Rule Assertion: Proposed RMR = User RMR
Appendix G Section: Transformers
Appendix G Section Reference: None
Data Lookup: None
Evaluation Context: Data Group
Applicability Checks:

  1. Number of transformers in User RMR greater than 0

Manual Checks: None

Rule Logic:

  • Applicability Check 1: length(U_RMR.transformers) > 0:
  • Calculate number of User RMR transformers num_user_transformers = length(U_RMR.transformers)
  • Calculate number of Proposed RMR transformers num_proposed_transformers = length(B_RMR.transformers)
  • Rule Assertion: num_user_transformers == num_proposed_transformers