Shutdown

Perform an emergency shutdown on the slivers in the given slice at this aggregate. Resources should be taken offline, such that experimenter access (on both the control and data plane) is cut off. No further actions on the slivers in the given slice should be possible at this aggregate, until an un-specified operator action restores the slice’s slivers (or deletes them). This operation is intended for operator use. The slivers are shut down but remain available for further forensics.

Call Syntax
Shutdown(string slice_urn, struct credentials[], struct options)

This operation is similar to ProtoGENI’s Shutdown operation. The SFA specification does not include this operation.

This operation is for operator use, to stop a misbehaving resource. Once shut down, the slivers are not available for experimenter use. The underlying resources may be returned to the pool of available resources, depending on resource type and aggregate implementation.

Argument 1: slice_urn

Supported by the server

Mandatory

Included by client

Mandatory

XML-RPC type

string

String content type

URN

Argument 2: credentials

The standard authorization argument. See the Credentials section.

Argument 3: options

A struct containing optional arguments, indexed by name. See General Options Argument Section.

No options are required.

Return Value

XML-RPC type

boolean

On success, the value field of the return struct will contain: XML-RPC boolean, indicating whether the resources associated with this reservation were successfully shut down to a state suitable for forensics. Return should be true, or else an error should be returned.

If the given slice has no resources locally, or was previously Shutdown, return shall be true, indicating the slice is shut down.

This method returns true (1), unless the resources remain running in the slice after this operation.

Return Codes and Errors

The Shutdown call can return the usual error codes: BADARGS, ERROR, SERVERERROR and UNAVAILABLE. See Error Codes for general errors.

Additionally, the Shutdown call can return the following error codes:

FORBIDDEN

Credential does not grant permission to a slice or sliver specified in the urns argument. Or the slice has been shut down.

EXPIRED

The slice and/or sliver has already expired.

SEARCHFAILED

The slice or sliver does not exist at this AM.

BUSY

Slice or sliver is temporarily locked, try again later

INPROGRESS

Shutdown already in progress