Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

OASYS - Info block - Sys Plot (Top View) #234

Open
JoernSeltmann opened this issue Sep 2, 2022 · 7 comments
Open

OASYS - Info block - Sys Plot (Top View) #234

JoernSeltmann opened this issue Sep 2, 2022 · 7 comments
Assignees

Comments

@JoernSeltmann
Copy link

I had problems understanding the plot in "Sys Plot (Top View)" of "Shadow PostProcessor -> Info".
In my mind the term "top view" implies a vantage point above the beamline. Unfortunately the X coordinate in the plot is displayed upward by default which would be a bottom view in Shadow coordinates. So if you have a "Plane Mirror" with "O.E. Orientation angle [deg]" of 90 degrees, the "Top Plot" seems to indicate a deflection to the right:
grafik

Could the plot be displayed with X coordinate downward by default instead to make it easier for newbies like me?

@srio
Copy link
Member

srio commented Sep 2, 2022

Hello,
I do not understand what is the problem. You clearly see that, when you travel with the beam, the deflection is to the right, as you said. The view is from a point at z positive and large (z>>0). Note that here the x,y,z are the LAB coordinates, not the screen or mirror coordinates.
Rgds, M

@JoernSeltmann
Copy link
Author

JoernSeltmann commented Sep 2, 2022

In SHADOW User Guide - Trace (V2.0) a 90 degree "Orientation Angle" means a deflection to the left, as the negative X values in my plot from the LAB coordinates "clearly" show.
So thanks for proving my point, I guess?!
grafik

@srio
Copy link
Member

srio commented Sep 2, 2022

Yes, I see. The top view in the LAB system ( (a) in the picture) would correspond to positive x's looking down.
I kept this issue open until that is changed.
Thanks a lot for reporting this.

@srio srio self-assigned this Sep 2, 2022
@lucarebuffi
Copy link
Member

I warmly suggest to avoid this sarcastic and disrespectful tone. We are trying to help, as we do with all the users. Please reconsider the approach to this interaction with us, otherwise I will close the issue and you'll find your answers elsewhere.

Best, L.R.

@JoernSeltmann
Copy link
Author

I meant no offense!
As I said I'm a newbie and not sure whether this has any point or what I'm missing to see the picture.
Please tell me what offended you and I'll edit my comment.

@JoernSeltmann
Copy link
Author

I think everything is plotted correct.
If you know the orientation of the lab system, where -X is left and +X is right, everything is fine.
But the wording of "Top view" with the X[mm]-axis oriented upward seems to imply otherwise.

@lucarebuffi
Copy link
Member

Thanks for clarifying. Hopefully we will be able to fix the issue asap.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment