Module config initialization - reset after setup #7

Open
kaklik opened this issue Jan 11, 2023 · 0 comments
Open

Module config initialization - reset after setup #7

kaklik opened this issue Jan 11, 2023 · 0 comments

Comments

@kaklik
Copy link
Contributor

kaklik commented Jan 11, 2023

Actually the fuel gauge IC needs to be configured and rebooted before permanent connection to the cells. The probably best way how to do that is to solder the cells with disabled output DC/DC converter. Then enable 3.3V converter X1 to supply fuel gauge IC U1.
In the current design is hard to do that because enable pin of X1 is permanently connected to the input power. The better solution should be to use a solder bridge, which could be soldered after the soldering of the input cell battery and after configuring the fuel gauge firmware parameters.

@kaklik kaklik changed the title Module config initialization Module config initialization - reset after setup Jan 24, 2023