# Generic modeling options file to run standard WISDEM case
General:
verbosity: False # When set to True, the code prints to screen many infos
WISDEM:
RotorSE:
flag: False
spar_cap_ss: Spar_Cap_SS
spar_cap_ps: Spar_Cap_PS
te_ss: TE_reinforcement_SS
te_ps: TE_reinforcement_PS
n_pitch_perf_surfaces: 5
n_tsr_perf_surfaces: 5
gust_std: 0.0
n_span: 60
n_pc: 50
DriveSE:
flag: False
TowerSE: # Options of TowerSE module
flag: True
wind: PowerWind # Wind used
gamma_f: 1.35 # Safety factor for fatigue loads
gamma_m: 1.3 # Safety factor for material properties
gamma_n: 1.0 # Safety factor for ...
gamma_b: 1.1 # Safety factor for ...
gamma_fatigue: 1.755 # Safety factor for fatigue loads
buckling_method: dnvgl # Buckling code type [eurocode or dnvgl]
buckling_length: 30 # Buckling parameter
soil_springs: False
gravity_foundation: False
frame3dd:
shear: True
geom: True
tol: 1e-7
FloatingSE:
flag: True
symmetric_moorings: True
gamma_f: 1.35 # Safety factor for fatigue loads
gamma_m: 1.3 # Safety factor for material properties
gamma_n: 1.0 # Safety factor for ...
gamma_b: 1.1 # Safety factor for ...
gamma_fatigue: 1.755 # Safety factor for fatigue loads
BOS:
flag: False
Loading:
mass: 967074.89012356
center_of_mass: [-6.61477744, -0.09771873, 4.53683107]
moment_of_inertia: [4.13558635e+08, 2.76071589e+08, 2.57350933e+08, 7.86163621e+02, 1.35359722e+07, 1.70976373e+05]
loads:
- force: [2427925.55809699, 29094.73368413, -7074256.2758736]
moment: [-278500.68674037, -12634193.44789813, 1299461.07383137]
velocity: 11.73732