Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathEcAlarm.h
686 lines (615 loc) · 26.9 KB
/
EcAlarm.h
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
/** Enterprise Control Configuration and Logging
Copyright (C) 2012 Free Software Foundation, Inc.
Written by: Richard Frith-Macdonald <[email protected]>
Date: Febrary 2010
Originally developed from 1996 to 2020 by Brainstorm, and donated to
the FSF.
This file is part of the GNUstep project.
This library is free software; you can redistribute it and/or
modify it under the terms of the GNU Lesser General Public
License as published by the Free Software Foundation; either
version 3 of the License, or (at your option) any later version.
This library is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
Library General Public License for more details.
You should have received a copy of the GNU Lesser General Public
License along with this library; if not, write to the Free
Software Foundation, Inc., 51 Franklin Street, Fifth Floor,
Boston, MA 02111 USA.
*/
#ifndef _ECALARM_H
#define _ECALARM_H
#import <Foundation/NSObject.h>
@class NSCoder;
@class NSDate;
@class NSDictionary;
@class NSString;
/**
* The EcAlarmEventType enumeration defines the different types of
* alarm we support.<br />
* The enumerated values MUST be matched by those in your SNMP MIB if
* you wish to have your software interact with SNMP tools.<br />
* NB. EcAlarmEventTypeUnknown must <em>NOT</em> be used in an alarm ...
* it is employed solely as a marker for the case where a lookup of
* type from probable cause can not determine a specific event type.
* <deflist>
* <term>EcAlarmEventTypeUnknown</term>
* <desc>Not used</desc>
* <term>EcAlarmEventTypeCommunications</term>
* <desc>A communications/networking/protocol issue</desc>
* <term>EcAlarmEventTypeEnvironmental</term>
* <desc>An external environmental issue (eg building on fire)</desc>
* <term>EcAlarmEventTypeEquipment</term>
* <desc>A hardware problem (eg disk failure)</desc>
* <term>EcAlarmEventTypeProcessingError</term>
* <desc>A software problem (a bug or misconfiguration)</desc>
* <term>EcAlarmEventTypeQualityOfService</term>
* <desc>A system not running as well as expected ... eg. overloaded</desc>
* </deflist>
*/
typedef enum {
EcAlarmEventTypeUnknown = 0,
EcAlarmEventTypeCommunications = 2,
EcAlarmEventTypeEnvironmental = 3,
EcAlarmEventTypeEquipment = 4,
EcAlarmEventTypeProcessingError = 10,
EcAlarmEventTypeQualityOfService = 11,
} EcAlarmEventType;
/** The EcAlarmProbableCause enumeration defines the probable causes of
* alarms produced by the system.<br />
* These are taken from the CCITT X.733 specification with the numeric
* values from the CCITT X.721 specification.<br />
* Enumeration values include a comment to specify which
* EcAlarmEventType they apply to.
* <deflist>
* <term>EcAlarmProbableCauseUnknown</term>
* <desc>Category: Any</desc>
* <term>EcAlarmAdapterError</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmApplicationSubsystemFailure</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmBandwidthReduced</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmCallEstablishmentError</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmCommunicationsProtocolError</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmCommunicationsSubsystemFailure</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmConfigurationOrCustomizationError</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmCongestion</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmCorruptData</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmCpuCyclesLimitExceeded</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmDataSetOrModemError</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmDegradedSignal</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmDTE_DCEInterfaceError</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmEnclosureDoorOpen</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmEquipmentMalfunction</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmExcessiveVibration</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmFileError</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmFireDetected</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmFloodDetected</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmFramingError</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmHeatingOrVentilationOrCoolingSystemProblem</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmHumidityUnacceptable</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmInputOutputDeviceError</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmInputDeviceError</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmLANError</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmLeakDetected</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmLocalNodeTransmissionError</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmLossOfFrame</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmLossOfSignal</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmMaterialSupplyExhausted</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmMultiplexerProblem</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmOutOfMemory</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmOutputDeviceError</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmPerformanceDegraded</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmPowerProblem</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmPressureUnacceptable</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmProcessorProblem</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmPumpFailure</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmQueueSizeExceeded</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmReceiveFailure</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmReceiverFailure</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmRemoteNodeTransmissionError</term>
* <desc>Category: Communications</desc>
* <term>EcAlarmResourceAtOrNearingCapacity</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmResponseTimeExcessive</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmRetransmissionRateExcessive</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmSoftwareProgramAbnormallyTerminated</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmSoftwareProgramError</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmStorageCapacityProblem</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmTemperatureUnacceptable</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmThresholdCrossed</term>
* <desc>Category: QoS</desc>
* <term>EcAlarmTimingProblem</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmToxicLeakDetected</term>
* <desc>Category: Environmental</desc>
* <term>EcAlarmTransmitFailure</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmTransmitterFailure</term>
* <desc>Category: Equipment</desc>
* <term>EcAlarmUnderlyingResourceUnavailable</term>
* <desc>Category: Processing</desc>
* <term>EcAlarmVersionMismatch</term>
* <desc>Category: Processing</desc>
* </deflist>
*/
typedef enum {
EcAlarmProbableCauseUnknown = 0, // Any
EcAlarmAdapterError = 1, // Equipment
EcAlarmApplicationSubsystemFailure = 2, // Processing
EcAlarmBandwidthReduced = 3, // QoS
EcAlarmCallEstablishmentError = 4, // Communications
EcAlarmCommunicationsProtocolError = 5, // Communications
EcAlarmCommunicationsSubsystemFailure = 6, // Communications
EcAlarmConfigurationOrCustomizationError = 7, // Processing
EcAlarmCongestion = 8, // QoS
EcAlarmCorruptData = 9, // Processing
EcAlarmCpuCyclesLimitExceeded = 10, // Processing
EcAlarmDataSetOrModemError = 11, // Equipment
EcAlarmDegradedSignal = 12, // Communications
EcAlarmDTE_DCEInterfaceError = 13, // Communications
EcAlarmEnclosureDoorOpen = 14, // Environmental
EcAlarmEquipmentMalfunction = 15, // Equipment
EcAlarmExcessiveVibration = 16, // Environmental
EcAlarmFileError = 17, // Processing
EcAlarmFireDetected = 18, // Environmental
EcAlarmFloodDetected = 19, // Environmental
EcAlarmFramingError = 20, // Communications
EcAlarmHeatingOrVentilationOrCoolingSystemProblem = 21, // Environmental
EcAlarmHumidityUnacceptable = 22, // Environmental
EcAlarmInputOutputDeviceError = 23, // Equipment
EcAlarmInputDeviceError = 24, // Equipment
EcAlarmLANError = 25, // Communications
EcAlarmLeakDetected = 26, // Environmental
EcAlarmLocalNodeTransmissionError = 27, // Communications
EcAlarmLossOfFrame = 28, // Communications
EcAlarmLossOfSignal = 29, // Communications
EcAlarmMaterialSupplyExhausted = 30, // Environmental
EcAlarmMultiplexerProblem = 31, // Equipment
EcAlarmOutOfMemory = 32, // Processing
EcAlarmOutputDeviceError = 33, // Equipment
EcAlarmPerformanceDegraded = 34, // QoS
EcAlarmPowerProblem = 35, // Equipment
EcAlarmPressureUnacceptable = 36, // Environmental
EcAlarmProcessorProblem = 37, // Equipment
EcAlarmPumpFailure = 38, // Environmental
EcAlarmQueueSizeExceeded = 39, // QoS
EcAlarmReceiveFailure = 40, // Equipment
EcAlarmReceiverFailure = 41, // Equipment
EcAlarmRemoteNodeTransmissionError = 42, // Communications
EcAlarmResourceAtOrNearingCapacity = 43, // QoS
EcAlarmResponseTimeExcessive = 44, // QoS
EcAlarmRetransmissionRateExcessive = 45, // QoS
EcAlarmSoftwareProgramAbnormallyTerminated = 47, // Processing
EcAlarmSoftwareProgramError = 48, // Processing
EcAlarmStorageCapacityProblem = 49, // Processing
EcAlarmTemperatureUnacceptable = 50, // Environmental
EcAlarmThresholdCrossed = 51, // QoS
EcAlarmTimingProblem = 52, // Equipment
EcAlarmToxicLeakDetected = 53, // Environmental
EcAlarmTransmitFailure = 54, // Equipment
EcAlarmTransmitterFailure = 55, // Equipment
EcAlarmUnderlyingResourceUnavailable = 56, // Processing
EcAlarmVersionMismatch = 57, // Processing
} EcAlarmProbableCause;
/** The EcAlarmSeverity enumeration defines the 'perceived severities' of
* alarms produced by the system.<br />
* The enumerated values MUST be matched by those in your SNMP MIB if
* you wish to have your software interact with SNMP tools.<br />
* NB. The use of EcAlarmSeverityIndeterminate should be avoided.
* <deflist>
* <term>EcAlarmSeverityIndeterminate</term><desc>Do not use</desc>
* <term>EcAlarmSeverityCritical</term>
* <desc>Immediate intervention required to restore service</desc>
* <term>EcAlarmSeverityMajor</term>
* <desc>Severe but partial system failure or a problem which
* might recover without intervention</desc>
* <term>EcAlarmSeverityMinor</term>
* <desc>A failure, but one which is likely to recover or which is
* probably not urgent</desc>
* <term>EcAlarmSeverityWarning</term>
* <desc>An unusual event which may not indicate any problem, but
* which ought to be looked into</desc>
* <term>EcAlarmSeverityCleared</term>
* <desc>This indicates the resolution of an earlier issue</desc>
* </deflist>
*/
typedef enum {
EcAlarmSeverityIndeterminate = 0,
EcAlarmSeverityCritical = 1,
EcAlarmSeverityMajor = 2,
EcAlarmSeverityMinor = 3,
EcAlarmSeverityWarning = 4,
EcAlarmSeverityCleared = 5
} EcAlarmSeverity;
/** The EcAlarmTrend enumeration defines the severity trend of alarms
* produced by the system.<br />
* The enumerated values MUST be matched by those in your SNMP MIB if
* you wish to have your software interact with SNMP tools.<br />
* <deflist>
* <term>EcAlarmTrendNone</term>
* <desc>This is not a change in severity of an earlier alarm</desc>
* <term>EcAlarmTrendUp</term>
* <desc>This is a more severe version of an earlier alarm</desc>
* <term>EcAlarmTrendDown</term>
* <desc>This is a less severe version of an earlier alarm</desc>
* </deflist>
*/
typedef enum {
EcAlarmTrendNone = 0,
EcAlarmTrendUp = '+',
EcAlarmTrendDown = '-',
} EcAlarmTrend;
/** This function builds a managed object name from host, process,
* and component.<br />
* The host part may be nil ... for the current host.<br />
* The process part may be nil ... for the current process.<br />
* The component may well be nil if the alert applies to the process as
* a whole rather than to a particular component. This field is typically
* used to identify a particular network connection etc within a process.<br />
* This parses the process and separates out any instance ID (trailing
* hyphen and string of digits). It then builds the managed object from
* four parts (host, process, instance, component) separated by underscores.
* Any underscores in the arguments are replaced by hyphens.<br />
* NB. The total length must not exceed 127 ASCII characters.
*/
NSString *
EcMakeManagedObject(NSString *host, NSString *process, NSString *component);
/** <p>The EcAlarm class encapsulates an alarm to be sent out to a monitoring
* system. It's designed to work cleanly with industry standard SNMP
* alarm monitoring systems. For more information on how the SNMP
* operation works, see the [EcAlarmSinkSNMP] class documentation.
* </p>
* <p>Instances are created and sent to a central coordination point
* where checks are performed to see if there is an existing alarm for
* the same issue. If the incoming alarm does not change the severity
* of an existing alarm, it is ignored, otherwise it may be passed on to
* an external monitoring system. The central coordination system is
* responsible for ensuring that alarms for the same issue are updated
* to contain the first event date, notification ID and a trend indicator.
* </p>
* <p>Alarms which have been raised (by passing them to an alarm destination)
* remain raised until they are cleared (by passign a matching alarm with
* a cleared severity status) to the destination. Alarm clears sent with
* no earlier matching raise are generally ignored, but a clear may be
* flagged as a special audit alarm: one which is passed on and logged
* for audit porposes. This is a rare situation where the alarm does not
* actually represent a problem (or even the suspicion of a problem).
* </p>
*/
@interface EcAlarm : NSObject <NSCoding,NSCopying>
{
NSString *_managedObject;
NSDate *_eventDate;
NSDate *_firstEventDate;
EcAlarmEventType _eventType;
EcAlarmSeverity _perceivedSeverity;
EcAlarmProbableCause _probableCause;
NSString *_specificProblem;
NSString *_proposedRepairAction;
NSString *_additionalText;
EcAlarmTrend _trendIndicator;
int _notificationID;
NSDictionary *_userInfo;
void *_extra;
BOOL _frozen;
uint8_t _delay;
BOOL _audit;
}
/** Creates and returns an autoreleased instance by calling the
* designated initialiser with all the supplied arguments.
*/
+ (EcAlarm*) alarmForManagedObject: (NSString*)managedObject
at: (NSDate*)eventDate
withEventType: (EcAlarmEventType)eventType
probableCause: (EcAlarmProbableCause)probableCause
specificProblem: (NSString*)specificProblem
perceivedSeverity: (EcAlarmSeverity)perceivedSeverity
proposedRepairAction: (NSString*)proposedRepairAction
additionalText: (NSString*)additionalText;
/** This method provides a mapping from the probable cause of an event to
* the event type.<br />
* The method is called during initialisation of an alarm instance (except
* where the probable cause is EcAlarmProbableCauseUnknown) to check that the
* supplied arguments are consistent. If a subclass extends the possible
* probable cause values, it must also override this method to handle those
* new values by returning a known event type.
*/
+ (EcAlarmEventType) eventTypeFromProbableCause: (EcAlarmProbableCause)value;
/** Provides a human readable string representation of an event type.<br />
* This method is called during initialisation of an alarm instance to check
* that the supplied event type is legal.<br />
* Returns nil if the value is unknown.<br />
*/
+ (NSString*) stringFromEventType: (EcAlarmEventType)value;
/** Provides a human readable string representation of a probable cause.<br />
* Returns nil if the value is unknown.
*/
+ (NSString*) stringFromProbableCause: (EcAlarmProbableCause)value;
/** Provides a human readable string representation of a severity.<br />
* Returns nil if the value is unknown.
*/
+ (NSString*) stringFromSeverity: (EcAlarmSeverity)value;
/** Provides a human readable string representation of a trend.<br />
* Returns nil if the value is unknown.
*/
+ (NSString*) stringFromTrend: (EcAlarmTrend)value;
/** This is the supplementary text (optional) which may be provided with
* and alarm an an aid to the human operator for the monitoring system.
*/
- (NSString*) additionalText;
/** Returns YES if this alarm is flagged as an audit object: a clear which
* should be recorded/monitored even without a matching raise of the alarm.
*/
- (BOOL) audit;
/** Compares the other object with the receiver for sorting/ordering.<br />
* If both objects have a notificationID set then the result of the
* numeric comparison of those IDs is used.<br />
* Otherwise the result of the comparison orders the objects by
* managedObject, eventType, probableCause, and specificProblem.
*/
- (NSComparisonResult) compare: (EcAlarm*)other;
/** Returns an autoreleased copy of the receiver with the same notificationID
* but with a perceivedSeverity set to be EcAlarmSeverityCleared ... this may
* be used to clear the alarm represented by the receiver.
*/
- (EcAlarm*) clear;
/** EcAlarm objects may be copied. This method is provided to implement
* the NSCopying protocol.<br />
* A copy of an object does <em>not</em> copy any value provided by the
* -setExtra: method.<br />
* A copy of an object is not frozen.
*/
- (id) copyWithZone: (NSZone*)aZone;
/** Deallocates the receiver.
*/
- (void) dealloc;
/** Returns the queue delay set for this alarm (or zero if none was set).
*/
- (uint8_t) delay;
/** Returns YES if the receiver should be delayed in the queue past the
* supplied timestamp, NO otherwise.
*/
- (BOOL) delayed: (NSTimeInterval)at;
/** EcAlarm objects may be passed over the distributed objects system or
* archived. This method is provided to implement the NSCoding protocol.<br />
* An encoded copy of an object does <em>not</em> copy any value provided
* by the -setExtra: method.
*/
- (void) encodeWithCoder: (NSCoder*)aCoder;
/** Returns the timestamp of the event which generated the alarm.
*/
- (NSDate*) eventDate;
/** This method returns the type for event which generated the alarm.
*/
- (EcAlarmEventType) eventType;
/** Returns any extra information stored by the -setExtra: method.<br />
*/
- (void*) extra;
/** If this alarm is known to be represent an event updating the status of
* an existing alarm, this method returns the date of the initial event.
* otherwise it returns nil.
*/
- (NSDate*) firstEventDate;
/** Freeze the state of the receiver;
* no more calls to setters are permitted.<br />
* When a frozen alarm is copied, the new copy is <em>not</em> frozen.
*/
- (void) freeze;
/** Returns the hash of the receiver ... which is also the hash of its
* managedObject.
*/
- (NSUInteger) hash;
/** <init/>
* Initialises the receiver as an alarm for a particular event.<br />
* The managedObject argument may be nil if the alarm should use the
* default managed object value for the current process.<br />
* The eventDate argument may be nil if the alarm should use the current
* timestamp.<br />
* The managedObject, eventType, probableCause, and specificProblem
* arguments uniquely identify the issue for which an alarm is being
* produced.<br />
* The perceivedSeverity indicates the importance of the problem, with a
* value of EcAlarmSeverityCleared indicating that the problem is over.<br />
* A proposedRepairAction is mandatory (unless the severity is cleared)
* to provide the human operator with some sort of hint about how they
* should resolve the issue.
*/
- (id) initForManagedObject: (NSString*)managedObject
at: (NSDate*)eventDate
withEventType: (EcAlarmEventType)eventType
probableCause: (EcAlarmProbableCause)probableCause
specificProblem: (NSString*)specificProblem
perceivedSeverity: (EcAlarmSeverity)perceivedSeverity
proposedRepairAction: (NSString*)proposedRepairAction
additionalText: (NSString*)additionalText;
/** EcAlarm objects may be passed over the distributed objects system or
* archived. This method is provided to implement the NSCoding protocol.
*/
- (id) initWithCoder: (NSCoder*)aCoder;
/** Returns a flag indicating whether the receiver is equal to the other
* object. To be considered equal either:<br />
* The two objects must have equal managedObject values and equal (non-zero)
* notificationID values or<br />
* the two objects must have equal managedObject values,
* equal eventType values, equal probableCause values,
* and equal specificProblem values.<br />
* NB. you must not set two alarm instances to have the same notificationID
* values if they are not considered equal using the other criteria.
*/
- (BOOL) isEqual: (id)other;
/** Returns the managedObject value set when the receiver was initialised.
*/
- (NSString*) managedObject;
/** Returns the component of the managed object (if any).
*/
- (NSString*) moComponent;
/** Returns the host of the managed object.
*/
- (NSString*) moHost;
/** Returns the instance of the managed object (if any).
*/
- (NSString*) moInstance;
/** Returns the process name of the managed object including the instance
* separated from the main name by a hyphen. If the managed object has no
* process instance, this method simply returns the process name.
*/
- (NSString*) moInstancedProcess;
/** Returns the process name of the managed object.
*/
- (NSString*) moProcess;
/** Returns zero or the notificationID value most recently set by
* the -setNotificationID: method.
*/
- (int) notificationID;
/** Returns the perceivedSeverity set when the receiver was initialised.
*/
- (EcAlarmSeverity) perceivedSeverity;
/** Returns the proposedRepairAction set when the receiver was initialised.
*/
- (NSString*) proposedRepairAction;
/** Returns the probableCause set when the receiver was initialised.
*/
- (EcAlarmProbableCause) probableCause;
/** Specified if this alarm is to be flagged as an audit object: a clear which
* should be recorded/monitored even without a matching raise of the alarm.
*/
- (void) setAudit: (BOOL)flag;
/** Sets the number of seconds for which this alarm should be delayed in the
* queue to allow coalescing with other matching alarms. This defaults to
* zero so that there is no special delay in processing beyond that imposed
* by periodic queue flushing.
*/
- (void) setDelay: (uint8_t)delay;
/** Sets extra data for the current instance.<br />
* Extra data is not copied, archived, or transferred over DO, it is available
* only in the exact instance of the class in which it was set.
*/
- (void) setExtra: (void*)extra;
/** Sets the first event date for the receiver.<br />
* You should not normally call this as it is reserved for use by code
* which has matched the receiver to an existing alarm.
*/
- (void) setFirstEventDate: (NSDate*)firstEventDate;
/** Sets the notification ID for the receiver.<br />
* You should not normally call this as it is reserved for use by code
* which has matched the receiver to an existing alarm.<br />
* In particular, two instances should not be set to have the same non-zero
* notificationID unless they are equal according to other criteria of
* equality (ie have the same managedObject, eventType, probableCause,
* and specificProblem values).
*/
- (void) setNotificationID: (int)notificationID;
/** Sets the trend indicator for the receiver.<br />
* You should not normally call this as it is reserved for use by code
* which has matched the receiver to an existing alarm.
*/
- (void) setTrendIndicator: (EcAlarmTrend)trendIndicator;
/** Sets the user information associated with this alarm (a dictionary).<br />
* This user information is additional data associated with the alarm
* which is copied when the alarm is copied. This data is not used by
* the CCITT X.733 ... it's optional additional data.<br />
* Conventional keys are:<br />
* <deflist>
* <term>ResponsibleEmail</term>
* <desc>The Email address of the person/entity with primary responsibility
* for dealing with an alarm ... this is intended for use by the alerting
* system (EcAlerter) when deciding where to send email alerts.
* </desc>
* </deflist>
*/
- (void) setUserInfo: (NSDictionary*)userInfo;
/** Returns the specificProblem set when the receiver was initialised.
*/
- (NSString*) specificProblem;
/** Returns the value most recently set by the -setTrendIndicator: method
* (or EcAlarmTrendNone if that method has not been called).<br />
* This tells you whether the receiver represents an increase in severity
* of an issue, or a decrease in severity (or no change).
*/
- (EcAlarmTrend) trendIndicator;
/** Returns any previously set information (see -setUserInfo:) or nil
* if none has been set.
*/
- (NSDictionary*) userInfo;
@end
@interface EcAlarm (Convenience)
/** Generates an alarm to clears an alarm previously generated.<br />
* The componentName may be nil for a process-wide alarm.<br />
* The probableCause must NOT be unknown ... it is used to infer
* the event type.<br />
* The specificProblem must be identical to the value supplied in the
* original alarm that this is intended to clear.
*/
+ (EcAlarm*) clear: (NSString*)componentName
cause: (EcAlarmProbableCause)probableCause
problem: (NSString*)specificProblem;
/** Generates a new alarm event with minimal parameters.<br />
* The componentName may be nil for a process-wide alarm.<br />
* The probableCause must NOT be unknown ... it is used to infer
* the event type.<br />
* The specificProblem is used to identify the event for which the
* alarm is raised.<br />
* The perceivedSeverity must be one of EcAlarmSeverityWarning,
* EcAlarmSeverityMinor, EcAlarmSeverityMajor or EcAlarmSeverityCritical.<br />
* The proposedRepairAction must contain information sufficient
* for any person receiving notification of the alarm to be able
* to deal with it. The action is a format string, optionally
* followed by any number of arguments to be incorporated into
* the repair action. NB. The resulting proposed repair action
* must be no more than 255 bytes in length when converted to
* UTF-8 data.
*/
+ (EcAlarm*) raise: (NSString*)componentName
cause: (EcAlarmProbableCause)probableCause
problem: (NSString*)specificProblem
severity: (EcAlarmSeverity)perceivedSeverity
action: (NSString*)proposedRepairAction, ...;
@end
#endif