# Vaillant Monitor Client (vwmon-client) for FRITZ!Box Configuration File
# Alexey Ozerov (c) 2013 - ver. 0.10
# All settings are optional
#######################################################################
# ebusd Host/Port
ebusd_Host localhost
ebusd_Port 7777
ebusd_Command /usr/bin/ebusd/ebusd -l ERR,WAR,INF -d /dev/ttyUSB0 -p 7777 -t >> /var/log/ebusd.log &
# Set RunInterval in seconds in order to run vwmon-client continuously
RunInterval 60
# Send all kind of errors via email (requires vwmon-server to be configured)
Error_Email [email protected]
# Full URL of frewe-server.php
VWMonServer_URL http://www.myserver.com/path/to/vwmon-server.php
# Server key as defined in vwmon-server.php
VWMonServer_Key my_server_key
# Send heatpump data to vwmon-server, set On to enable
VWMonServer_SendData On
# Accept commands from VWMon-Control, set On to enable
VWMonServer_Commands On
# What to send if some value is not available
ErrorString NULL
FHEM_File /opt/vwmon/fhem.txt
FHEM_ErrorString NULL
# Anything else will define fields and commands
amu_wp_stat get amu wp_stat
amu_comp_h_sum get amu comp_h_sum
amu_comp_starts get amu comp_starts
amu_boiler_h_sum get amu boiler_h_sum
amu_boiler_starts get amu boiler_starts
mv_yield_sum get mv yield_sum
mv_brine_in_temp get mv brine_in temp
mv_brine_out_temp get mv brine_out temp
mv_brine_press_press get mv brine_press press
mv_brine_press_stat get mv brine_press_stat
mv_high_press_press get mv high_press press
mv_low_press_press get mv low_press press
mv_overheat_temp get mv overheat_temp
mv_undercool_temp get mv undercool_temp
mv_EI_current get mv EI_current
mv_comp_in_temp_temp get mv comp_in_temp temp
mv_comp_out_temp_temp get mv comp_out_temp temp
mv_tev_in_temp_temp get mv tev_in_temp temp
mv_comp_io get mv comp_io
mv_boiler_io get mv boiler_io
mv_T6_temp_temp get mv T6_temp temp
mv_T5_temp_temp get mv T5_temp temp
mv_heat_press_press get mv heat_press press
mv_heat_pump_io get mv heat_pump_io
# mv_VF1_temp_temp get mv VF1_temp temp
# mv_RF1_temp_temp get mv RF1_temp temp
mv_VF2_temp_temp get mv VF2_temp temp
ci_cir2_set_temp get ci cir2_set_temp
mv_mixer_stat get mv mixer_stat
mv_pump_stat get mv pump_stat
mv_boiler_temp_temp get mv boiler_temp temp
mv_circ_pump_io get mv circ_pump_io
mv_valve get mv valve
mv_power_interrupt get mv power_interrupt
mv_at_temp_temp get mv at_temp temp
hw_mode get hw mode
hw_temp get hw temp
hw_min_temp get hw min_temp
cir2_rt_day get cir2 rt_day
cir2_rt_night get cir2 rt_night
cir2_curve get cir2 curve
cir2_at_off get cir2 at_off
# END OF FILE