****** This is the compressor test case from p. 167 of theory & user manual, 01/04/05
PERFORM
TITLE EXAMPLE CASE FOR COMPRESSOR WITH ROOTS POCKET OPTION, 01/04/05
CASEA VCOMP 0000 3 4 0
CASEB 0 0 0 0 0
CASEC 0.0 0.0 0.0
CASED 0.0
PARAM 15
****************************************************************
VALUES 1 1.0 158.5674 595.45 122.026 1140.
VALUES 6 1.74 .85 .000369 .9
VALUES 11 0.04 200.0000 600.00 121.100
********************************************************************
RINLET 20 1 30100 1 2 3 4 3 -22
RINLET 22 3 50000 11 12 13 14 3 -22
********************************************************************
SHAFT 30 1 0 5
********************************************************************
VCOMP 40 1 3 9 1 0 6 71 72 7 2 8 5 3 2 9
********************************************************************
ROUTLT 70 2 90000 1 2 3 4
********************************************************************
TABID 71 4 33 0 0 280101 2 0 101 101 2
TABT VCOMP: PRESSURE RATIO = F(FLOW RATE,SHAFT SPEED)
TABV 0.0 1.0
TABV 0.0 11.0
TABV 1000. 11000.
TABV 2.0 1.0 20.0 1.0
********************************************************************
TABID 72 6 33 0 0 280101 2 0 101 101 2
TABT VCOMP: EFFICIENCY = F(FLOW RATE,SHAFT SPEED)
TABV 0.0 1.0
TABV 0.0 11.0
TABV 1000. 11000.
TABV 0.85 0.85 0.85 0.85
********************************************************************
PTAB 1 0 1 0
********************************************************************
ENDCASE
ENDJOB