Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathKaifa_v4_Telegram.txt
150 lines (138 loc) · 6 KB
/
Kaifa_v4_Telegram.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
-- Kaifa Telegram Definition
/KFM5KAIFA-METER
1-3:0.2.8(42) Version information for P1 output
0-0:1.0.0(180605091333S) Date-time stamp of the P1 message
0-0:96.1.1(4530303236303030303133343837363135) Equipment identifier
1-0:1.8.1(001790.476*kWh) Electricity delivered TO client (Tariff 1) in 0,001 kWh
1-0:1.8.2(002320.188*kWh) Electricity delivered TO client (Tariff 2) in 0,001 kWh
1-0:2.8.1(000000.000*kWh) Electricity delivered BY client (Tariff 1) in 0,001 kWh
1-0:2.8.2(000000.000*kWh) Electricity delivered BY client (Tariff 2) in 0,001 kWh
0-0:96.14.0(0002) Tariff indicator electricity. The tariff indicator can also be used to switch tariff dependent loads e.g.boilers
1-0:1.7.0(00.258*kW) Actual electricity power delivered (+P) in 1 Watt resolution
1-0:2.7.0(00.000*kW) Actual electricity power received (-P) in 1 Watt resolution
0-0:96.7.21(00010) Number of power failures in any phase
0-0:96.7.9(00004) Number of long power failures in any phase
1-0:99.97.0(1)(0-0:96.7.19)(000101000011W)(2147483647*s) Power Failure Event Log (long power failures)
1-0:32.32.0(00000) Number of voltage sags in phase L1
1-0:52.32.0(00000) Number of voltage sags in phase L2 (polyphase meters only)
1-0:72.32.0(00000) Number of voltage sags in phase L3 (polyphase meters only)
1-0:32.36.0(00000) Number of voltage swells in phase L1
1-0:52.36.0(00000) Number of voltage swells in phase L2 (polyphase meters only)
1-0:72.36.0(00000) Number of voltage swells in phase L3 (polyphase meters only)
0-0:96.13.1() Text message codes: numeric 8 digits
0-0:96.13.0() Text message max 1024 characters.
1-0:31.7.0(000*A) Instantaneous current L1
1-0:51.7.0(000*A) Instantaneous current L2
1-0:71.7.0(000*A) Instantaneous current L3
1-0:32.7.0(000*V) ?? Instantaneous voltage L1 ??
1-0:52.7.0(000*V) ?? Instantaneous voltage L2 ??
1-0:72.7.0(000*V) ?? Instantaneous voltage L3 ??
1-0:21.7.0(00.125*kW) Instantaneous active power L1 (+P)
1-0:22.7.0(00.000*kW) Instantaneous active power L1 (-P)
1-0:41.7.0(00.124*kW) Instantaneous active power L2 (+P)
1-0:42.7.0(00.000*kW) Instantaneous active power L2 (-P)
1-0:61.7.0(00.009*kW) Instantaneous active power L3 (+P)
1-0:62.7.0(00.000*kW) Instantaneous active power L3 (-P)
0-1:24.1.0(003) (Gas) Device-Type (channel)
0-1:96.1.0(4730303235303033333436333738353136) (Gas) Equipment identifier
0-1:24.2.1(180605090000S)(05225.708*m3) (Gas) Last hourly (or 5-minute?) value (temperature converted), gas delivered to client in m3, including decimal values and capture time
!F7F2
-- My Telegram Integrations
sensors/power/p1meter/received_tarif_1
sensors/power/p1meter/received_tarif_2
sensors/power/p1meter/actual_consumption
sensors/power/p1meter/actual_received
sensors/power/p1meter/instant_power_return_l1
sensors/power/p1meter/instant_power_return_l2
sensors/power/p1meter/instant_power_return_l3
sensors/power/p1meter/instant_power_current_l1
sensors/power/p1meter/instant_power_current_l2
sensors/power/p1meter/instant_power_current_l3
sensors/power/p1meter/instant_voltage_l1
sensors/power/p1meter/instant_voltage_l2
sensors/power/p1meter/instant_voltage_l3
sensors/power/p1meter/actual_tarif_group
sensors/power/p1meter/
sensors/power/p1meter/
sensors/power/p1meter/
sensors/power/p1meter/
sensors/power/p1meter/gas_meter_m3
-- Debug Output
/KFM5KAIFA-METER
1-3:0.2.8(42)
0-0:1.0.0(220418200220S)
0-0:96.1.1(4530303033303030303038343133323134)
1-0:1.8.1(004576.586*kWh)
1-0:1.8.2(004282.105*kWh)
1-0:2.8.1(001449.452*kWh)
1-0:2.8.2(003258.397*kWh)
0-0:96.14.0(0001)
1-0:1.7.0(00.114*kW)/KFM5KAIFA-METER
1-3:0.2.8(42)
0-0:1.0.0(220418200319S)
0-0:96.1.1(4530303033303030303038343133323134)
1-0:1.8.1(004576.589*kWh)
1-0:1.8.2(004282.105*kWh)
1-0:2.8.1(001449.452*kWh)
1-0:2.8.2(003258.397*kWh)
0-0:96.14.0(0001)
1-0:1.7.0(00.237*kW)
1-0:2.7.0(00.000*kW)
0-0:96.7.21(00016)
0-0:96.7.9(00008)
1-0:99.97.0(3)(0-0:96.7.19)(171215160515W)(0000010612*s)(171207094401W)(0045932662*s)(000101000017W)(2147483647*s)
1-0:32.32.0(00000)
1-0:52.32.0(00000)
1-0:72.32.0(00000)
1-0:32.36.0(00000)
1-0:52.36.0(00000)
1-0:72.36.0(00000)
0-0:96.13.1()
0-0:96.13.0()
1-0:31.7.0(000*A)
1-0:51.7.0(000*A)
1-0:71.7.0(001*A)
1-0:21.7.0(00.000*kW)
1-0:22.7.0(00.000*kW)
1-0:41.7.0(00.009*kW)
1-0:42.7.0(00.000*kW)
1-0:61.7.0(00.229*kW)
1-0:62.7.0(00.000*kW)
0-1:24.1.0(003)
0-1:96.1.0(4730303032333430323032393135393135)
0-1:24.2.1(220418190000S)(03562.851*m3)
!5ABF
Sending: consumption_tarif_1 value: 4576589
Sending: consumption_tarif_2 value: 4282105
Sending: produced_tarif_1 value: 1449452
Sending: produced_tarif_2 value: 3258397
Sending: actual_consumption value: 237
Sending: actual_produced value: 0
Sending: instant_power_usage_l1 value: 0
Sending: instant_power_usage_l2 value: 9
Sending: instant_power_usage_l3 value: 229
Sending: instant_power_return_l1 value: 0
Sending: instant_power_return_l2 value: 0
Sending: instant_power_return_l3 value: 0
Sending: instant_power_current_l1 value: 0
Sending: instant_power_current_l2 value: 0
Sending: instant_power_current_l3 value: 1000
Sending: actual_tarif_group value: 1
Sending: gas_meter_m3 value: 3562851
1-0:1.8.1 : consumption_tarif_1 : 4576589
1-0:1.8.2 : consumption_tarif_2 : 4282105
1-0:2.8.1 : produced_tarif_1 : 1449452
1-0:2.8.2 : produced_tarif_2 : 3258397
1-0:1.7.0 : actual_consumption : 237
1-0:2.7.0 : actual_produced : 0
1-0:21.7.0 : instant_power_usage_l1 : 0
1-0:41.7.0 : instant_power_usage_l2 : 9
1-0:61.7.0 : instant_power_usage_l3 : 229
1-0:22.7.0 : instant_power_return_l1 : 0
1-0:42.7.0 : instant_power_return_l2 : 0
1-0:62.7.0 : instant_power_return_l3 : 0
1-0:31.7.0 : instant_power_current_l1 : 0
1-0:51.7.0 : instant_power_current_l2 : 0
1-0:71.7.0 : instant_power_current_l3 : 1000
0-0:96.14.0 : actual_tarif_group : 1
0-1:24.2.1 : gas_meter_m3 : 3562851