Examine the output of the ceph -s
command to get context for potential issues causing latency.
Troubleshoot the underlying causes for the ceph -s
command reporting slow PGs.
This procedure requires admin privileges.
-
View the status of Ceph.
ceph -s
Example output:
cluster: id: 73084634-9534-434f-a28b-1d6f39cf1d3d health: HEALTH_WARN 1 filesystem is degraded 1 MDSs report slow metadata IOs Reduced data availability: 15 pgs inactive, 15 pgs peering 46 slow ops, oldest one blocked for 1395 sec, daemons [osd,2,osd,5,mon,ceph-1,mon,ceph-2,mon,ceph-3] have slow ops. services: mon: 3 daemons, quorum ceph-3,ceph-1,ceph-2 (age 38m) mgr: ceph-2(active, since 30m), standbys: ceph-3, ceph-1 mds: cephfs:1/1 {0=ceph-2=up:replay} 2 up:standby osd: 15 osds: 15 up (since 93s), 15 in (since 23m); 10 remapped pgs rgw: 1 daemon active (ceph-1.rgw0) data: pools: 9 pools, 192 pgs objects: 15.93k objects, 55 GiB usage: 175 GiB used, 27 TiB / 27 TiB avail pgs: 7.812% pgs not active 425/47793 objects misplaced (0.889%) 174 active+clean 8 peering 7 remapped+peering 2 active+remapped+backfill_wait 1 active+remapped+backfilling io: client: 7.0 KiB/s wr, 0 op/s rd, 1 op/s wr recovery: 12 MiB/s, 3 objects/s
The output can provide a lot of context to potential issues causing latency. In the example output above, the following troubleshooting information can be observed:
- health - Shows latency and what daemons/OSDs are associated with it.
- mds - MDS is functional, but it is in replay because of the slow ops.
- osd - All OSDs are up and in. This could be related to a network issue or a single system issue if both OSDs are on the same box.
- client - Shows the amount of IO/Throughput that clients using Ceph are performing. If health is not set to HEALTH_OK and traffic is passing through, then Ceph is functioning and re-balancing data because of typical hardware/network issues.
- recovery - Shows recovery traffic as the system ensures all the copies of data are available to ensure data redundancy.
Based on the output from ceph -s
(using our example above) we can correlate some information to help determine our bottleneck.
-
When reporting slow ops for OSDs, then it is good to find out if those OSDs are on the same node or different nodes.
- If the OSDs are on the same node, then look at networking or other hardware-related issues on that node.
- If the OSDs are on different nodes, then investigate networking issues.
- As an initial step, restart the OSDs, if the slow ops go away and do not return, then we can investigate the logs for possible software bugs or memory issues.
- If the slow ops come right back, then there is an issue with replication between the 2 OSDs which tends to be network-related.
-
When reporting slow ops for
MONs
, then it is typically an issue with the process. The most common cause is either an abrupt clock skew or a hung mon/mgr process.-
The recommended remediation is to do a rolling restart of the Ceph
MON
andMGR
daemons.-
Get
MON
andMGR
daemons.ceph orch ps | grep -E 'mgr|mon'
-
Restart each
MON
andMGR
daemons. Make sure each daemon starts before restarting the next one.ceph orch daemon restart <daemon_name>
-
-
Failover the active MDS server.
ceph mds fail 0
-
-
When reporting slow ops for MDS, then are multiple possible causes.
- If listed in addition to OSDs, then the root cause for this is typically the OSDs, and the process above should be used, followed by restarting the
MDS
daemons. - If it is only listing MDS, then restart the MDS daemons. If the problem persists, then examine the logs in order to determine the root cause.
- See Troubleshoot Ceph MDS reporting slow requests and failure on client for additional steps to help identify MDS slow ops