UPDATE: Uploaded V2 to fix one of the power ratings that was the wrong OID. It was collecting watts incorrectly. All fixed now!
This APC Template contains outlet discovery and should work with any managed or switched APC PDU.
Contains sane triggers, load status, graphs, etc.
Triggers: APC Load State, Load Change, Power Alarm, etc.
Items: Basic information (model, name, firmware, etc), Power load/peak/etc, Master States (Enable for older units), All APC value mappings, and much more.
Graphs: Load and Current
Outlet Status (Dynamic Discovery)
Please enjoy and vote!
Name | Description | Default | Type |
---|---|---|---|
{$SNMP_COMMUNITY} | - |
public |
Text macro |
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
Outlets | - |
SNMP agent |
rPDU2Outlet Update: 3600 |
Name | Description | Type | Key and additional info |
---|---|---|---|
rPDU2DeviceStatusPeakPower.1 | - |
SNMP agent |
rPDU2DeviceStatusPeakPower.1 Update: 300 |
rPDU2IdentName.1 | - |
SNMP agent |
rPDU2IdentName.1 Update: 86400 |
rPDU2PhaseStatusPeakCurrent.1 | - |
SNMP agent |
rPDU2PhaseStatusPeakCurrent.1 Update: 30 |
rPDU2IdentFirmwareRev.1 | - |
SNMP agent |
rPDU2IdentFirmwareRev.1 Update: 600 |
rPDU2PhaseStatusVoltage.1 | - |
SNMP agent |
rPDU2PhaseStatusVoltage.1 Update: 30 |
sPDUMasterState.0 | - |
SNMP agent |
sPDUMasterState.0 Update: 60 |
rPDU2DevicePropertiesMaxPhaseCurrentRating.1 | - |
SNMP agent |
rPDU2DevicePropertiesMaxPhaseCurrentRating.1 Update: 86400 |
rPDU2PhaseStatusCurrent.1 | - |
SNMP agent |
rPDU2PhaseStatusCurrent.1 Update: 30 |
rPDU2DeviceStatusPowerSupplyAlarm.1 | - |
SNMP agent |
rPDU2DeviceStatusPowerSupplyAlarm.1 Update: 30 |
rPDU2DeviceStatusPeakPowerTimestamp.1 | - |
SNMP agent |
rPDU2DeviceStatusPeakPowerTimestamp.1 Update: 300 |
rPDU2IdentLocation.1 | - |
SNMP agent |
rPDU2IdentLocation.1 Update: 86400 |
rPDU2GroupTotalEnergy.0 | - |
SNMP agent |
rPDU2GroupTotalEnergy.0 Update: 30 |
sPDUIdentModelNumber.0 | - |
SNMP agent |
sPDUIdentModelNumber.0 Update: 86400 |
rPDU2PhaseStatusPeakCurrentTimestamp.1 | - |
SNMP agent |
rPDU2PhaseStatusPeakCurrentTimestamp.1 Update: 300 |
rPDU2IdentModelNumber.1 | - |
SNMP agent |
rPDU2IdentModelNumber.1 Update: 86400 |
rPDU2DeviceStatusPower.1 | - |
SNMP agent |
rPDU2DeviceStatusPower.1 Update: 30 |
rPDU2IdentSerialNumber.1 | - |
SNMP agent |
rPDU2IdentSerialNumber.1 Update: 86400 |
sPDUMasterPending.0 | - |
SNMP agent |
sPDUMasterPending.0 Update: 60 |
rPDU2DeviceStatusLoadState.1 | - |
SNMP agent |
rPDU2DeviceStatusLoadState.1 Update: 30 |
sPDUIdentFirmwareRev.0 | - |
SNMP agent |
sPDUIdentFirmwareRev.0 Update: 600 |
Outlet $1 Name | - |
SNMP agent |
rPDU2OutletSwitchedConfigName[{#SNMPINDEX}] Update: 3600 LLD |
Outlet $1 Bank | - |
SNMP agent |
rPDU2OutletSwitchedPropertiesBank[{#SNMPINDEX}] Update: 86400 LLD |
Outlet $1 State | - |
SNMP agent |
rPDU2OutletSwitchedStatusState[{#SNMPINDEX}] Update: 60 LLD |
Name | Description | Expression | Priority |
---|---|---|---|
Outlet {#SNMPVALUE} State Change | - |
Expression: (last(/SNMP APC PDU/rPDU2OutletSwitchedStatusState[{#SNMPINDEX}],#1)<>last(/SNMP APC PDU/rPDU2OutletSwitchedStatusState[{#SNMPINDEX}],#2))=1 Recovery expression: |
information |
Outlet {#SNMPVALUE} State Change (LLD) | - |
Expression: (last(/SNMP APC PDU/rPDU2OutletSwitchedStatusState[{#SNMPINDEX}],#1)<>last(/SNMP APC PDU/rPDU2OutletSwitchedStatusState[{#SNMPINDEX}],#2))=1 Recovery expression: |
information |
UPDATE: Uploaded V2 to fix one of the power ratings that was the wrong OID. It was collecting watts incorrectly. All fixed now!
This APC Template contains outlet discovery and should work with any managed or switched APC PDU.
Contains sane triggers, load status, graphs, etc.
Triggers: APC Load State, Load Change, Power Alarm, etc.
Items: Basic information (model, name, firmware, etc), Power load/peak/etc, Master States (Enable for older units), All APC value mappings, and much more.
Graphs: Load and Current
Outlet Status (Dynamic Discovery)
Please enjoy and vote!
UPDATE: Uploaded V2 to fix one of the power ratings that was the wrong OID. It was collecting watts incorrectly. All fixed now!
This APC Template contains outlet discovery and should work with any managed or switched APC PDU.
Contains sane triggers, load status, graphs, etc.
Triggers: APC Load State, Load Change, Power Alarm, etc.
Items: Basic information (model, name, firmware, etc), Power load/peak/etc, Master States (Enable for older units), All APC value mappings, and much more.
Graphs: Load and Current
Outlet Status (Dynamic Discovery)
Please enjoy and vote!
There are no macros links in this template.
There are no template links in this template.
There are no discovery rules in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
upsBypassPower.1 | - |
SNMP agent |
upsBypassPower.1 Update: 30 |
upsIdentAgentSoftwareVersion | - |
SNMP agent |
upsIdentAgentSoftwareVersion Update: 600 |
upsOutputFrequency | - |
SNMP agent |
upsOutputFrequency Update: 30 |
upsBypassCurrent.1 | - |
SNMP agent |
upsBypassCurrent.1 Update: 30 |
upsAlarmsPresent | - |
SNMP agent |
upsAlarmsPresent Update: 30 |
upsBypassFrequency | - |
SNMP agent |
upsBypassFrequency Update: 30 |
upsSecondsOnBattery | - |
SNMP agent |
upsSecondsOnBattery Update: 30 |
upsIdentUPSSoftwareVersion | - |
SNMP agent |
upsIdentUPSSoftwareVersion Update: 600 |
upsInputVoltage.1 | - |
SNMP agent |
upsInputVoltage.1 Update: 30 |
upsBatteryTemperature | - |
SNMP agent |
upsBatteryTemperature Update: 60 |
upsEstimatedChargeRemaining | - |
SNMP agent |
upsEstimatedChargeRemaining Update: 60 |
upsInputFrequency.1 | - |
SNMP agent |
upsInputFrequency.1 Update: 30 |
upsBypassVoltage.1 | - |
SNMP agent |
upsBypassVoltage.1 Update: 30 |
upsEstimatedMinutesRemaining | - |
SNMP agent |
upsEstimatedMinutesRemaining Update: 30 |
upsInputLineBads | - |
SNMP agent |
upsInputLineBads Update: 30 |
upsOutputVoltage.1 | - |
SNMP agent |
upsOutputVoltage.1 Update: 30 |
upsOutputCurrent.1 | - |
SNMP agent |
upsOutputCurrent.1 Update: 30 |
upsOutputPower.1 | - |
SNMP agent |
upsOutputPower.1 Update: 30 |
upsBatteryVoltage | - |
SNMP agent |
upsBatteryVoltage Update: 60 |
upsOutputPercentLoad.1 | - |
SNMP agent |
upsOutputPercentLoad.1 Update: 30 |
upsOutputSource | - |
SNMP agent |
upsOutputSource Update: 30 |
upsBatteryStatus | - |
SNMP agent |
upsBatteryStatus Update: 30 |
upsIdentModel | - |
SNMP agent |
upsIdentModel Update: 86400 |
There are no triggers in this template.